欧美激情一区二区_国产人与动zozo_野外性史欧美k8播放_XXXX18HD亚洲HD护士_日韩欧美亚欧在线视频

您好,歡迎來到中國企業(yè)庫   [請登陸]  [免費注冊]
小程序  
APP  
微信公眾號  
手機版  
 [ 免責聲明 ]     [ 舉報 ]
客服電話:13631151688
企業(yè)庫首頁>資訊
行業(yè)
超級獵聘人才網(wǎng) 廣告

How long can the fire emergency light be used?

作者:Zhizhuo Optoelectronics Technology Co.,Ltd 來源:gdzhizhuo 發(fā)布時間:2020-04-29 瀏覽:984
How long can the fire emergency light be used?

    Fire emergency lighting with accumulator should be started at the same time of power failure. The switching time driven by fire emergency power should be within 5 seconds. For emergency lighting for evacuation, the minimum illumination of the ground shall not be lower than 0.5 lx. Emergency lighting and evacuation indicator signs can be used as backup power supply, and the continuous power supply time should not be less than 20min; The continuous power supply time of high-rise buildings with height over 100m should not be less than 30min.

According to the production standard of fire emergency lamp:


    the time of the system shall not be less than 90min and shall not be less than the nominal emergency working time of the lamp]

    GB 50016 -- code for fire protection in architectural design GB 50016 -- code for fire protection in architectural design GB 50016 -- code for fire protection in architectural design

    "Code for fire protection design of high-rise civil buildings" GB 50045-95 (2005 edition) 9.2.6 emergency lighting and evacuation indicator signs, can use battery as backup power, and the continuous power supply time should not be less than 20min; The continuous power supply time for high-rise buildings over 1OOm should not be less than 30min];


    Here refers to the application of fire emergency lights in the building design fire code, the construction engineering design unit with reference to the application of the fire emergency lights minimum emergency time;

    Fire evacuation indicator signs and fire emergency lighting fixtures installed in buildings in accordance with GB 50016 -- 11.3.6 of 2006 shall not only comply with the provisions of this code, but also comply with the relevant provisions of the current national standards fire safety signs GB 13495 and fire emergency lighting GB 17945.

鄭重聲明:資訊 【How long can the fire emergency light be used?】由 Zhizhuo Optoelectronics Technology Co.,Ltd 發(fā)布,版權歸原作者及其所在單位,其原創(chuàng)性以及文中陳述文字和內(nèi)容未經(jīng)(企業(yè)庫www.nnfsds.com)證實,請讀者僅作參考,并請自行核實相關內(nèi)容。若本文有侵犯到您的版權, 請你提供相關證明及申請并與我們聯(lián)系(qiyeku # qq.com)或【在線投訴】,我們審核后將會盡快處理。
會員咨詢QQ群:902340051 入群驗證:企業(yè)庫會員咨詢.
熱門資訊
免費注冊只需30秒,立刻尊享
免費開通旗艦型網(wǎng)絡商鋪
免費發(fā)布無限量供求信息
每天查看30萬求購信息